P/N 92219601 • Rev D7/2/2008
Warranty: If this unit fails during the warranty period, contact tii customer service to authorize return. Unit may be returned prepaid.
Model 355 & 356 Series
Station Protector Modules
Installation Note
Description
1. The TII 355 and TII 356 Series Station
Protector modules may be installed in a wide
variety of station protector and network
interface housings.
2. The TII 355 and TII 356 Series are self
clearing and generally should require no
maintenance.
3. It is possible, however, that successive
operations or the cumulative effect of heat
may cause failure of the gas tube. In case of
trouble, the entire protector module should be
replaced with a new unit.
4. National Electric Code Requirement. The
protector shall be installed per National
Electric Code ANSI/NFPA 70, Article 800,
Section C, and shall meet all applicable local
safety codes.
5. These modules shall be installed in NID
enclosures evaluated to the requirement of
UL497.
Installation
1. Loosen the nut on the appropriate ground stud
and slide the ground clip of the surge protector
module under the nut and washer and tighten
down the nut.
2. Ground the module using a No. 6 AWG solid
copper insulated ground wire. Connect one
end of the ground conductor to the appropriate
ground stud and the other end to an
appropriate ground source (Figure 2).
3. Terminate the Telco Side cable (i.e., aerial or
buried drop) in between the bottom set of
washers and bottom nut of the appropriate
stud (one conductor to Tip and one to Ring).
Tighten down the nut (Figure 1).
4. Terminate the Customer Side cable under the
top set of washers and the top nut of the
appropriate stud (one conductor to Tip and
one to Ring). Tighten down the nut (Figure 1).
Figure 1
141 Rodeo Drive
Edgewood, NY 11717
Toll Free 888.444.4720
www.tiinettech.com
Telco Side Cable
Terminate Between
Washers
Ground Clip
Customer Side
Cable
Terminate Between
Washers
Page view 0
1 2

Summary of Contents

Page 1 - Installation Note

P/N 92219601 • Rev D• 7/2/2008 Warranty: If this unit fails during the warranty period, contact tii customer service to authorize return. Unit may b

Page 2 - Precaution

5. Loop back unused station wire conductors and coil around the station wire jacket or store in such a manner as to prevent them from coming in con

Related models: 355 Series

Comments to this Manuals

No comments